| DataLink 600 | 
			Category 7+ S/FTP 100 Ohm Horizontal LAN Cables Tested to 1000 MHz  | 
			
| Description | 
| HCS DataLink 600 CAT 7+ cable series consists of 100 Ohm impedance, 4-pair and 8-pair S/FTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 7 requirements of IEC 61156-5 (Specified in ISO/IEC 11801) and are tested up to 1000MHz. These cables fully support all IEEE 802.3 PoE applications including Type 1 IEEE 802.3af 2008, Type 2 IEEE 802.3at 2009, Type 3 IEEE 802.3bt 2018 & Type 4 IEEE 802.3bt 2018, CISCO UPoE & UPoE+ and HDBase-T PoH. | 
| Application | |
| HCS DataLink 600 CAT 7+ Horizontal cables support all presently available and future LAN applications, including the following protocols: | |
| 
			☑ Broadband Digital and Analog 
			CATV signals up to 1000 MHz ☑ SOHO and multiple simultaneous applications on all 4 pairs ☑ IEEE 802.3an 10GBASE-T 10 Gigabit Ethernet ☑ 1000BASE-T 1 Gigabit Ethernet ☑ ATM 155 ☑ TP-PMD ☑ 100BASE-T "Fast Ethernet" ☑ 100BASE-T2 ☑ 100BASE-T4 ☑ 100BASE-TX ☑ Token Ring 100 Mbps ☑ ATM 52 ☑ ATM 25 ☑ 10BASE-T Ethernet ☑ Token Ring 4 Mbps and 16 Mbps ☑ Broadband and Baseband Video ☑ ISDN Basic and Primary Access ☑ 1BASE-5 Starlan ☑ ISALAN ☑ ITU V.21 and X.11  | 
			|
| 
			 Qualifications and Approvals  | 
		|
| HCS DataLink 600 CAT 7+ Cables are tested and verified for full compliance with the following standards: | |
| 
			☑ Category 7 according to IEC 
			61156-5 (for ISO/IEC-11801) ☑ 600 MHz according to CENELEC EN 50288-4  | 
		|
Benefits & Features  | 
		
| 
			→ 
			Exceptional transmission properties - suitable for 10GBE 
			applications on 100m channels. → Testing every reel of cable prior to shipment - providing the highest degree of quality assurance. → Exceptional material properties and cable design - providing a unique Century™ Lifetime Warranty. → High ACR values - providing low BER (Bit-Error-Rate) in all applications. → Extremely high pair-balance and double shield - providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and preventing any alien-crosstalk (AXT). → Revolutionary pair lay scheme - providing an extremely low delay skew. → Descending sequential meter mark - providing easy stock and left-over handling. → Smooth and rigid jacket - proving fast and easy cable pulling and installation. → Batch number printed every meter - providing fast retrieval of test results from data-base. → A comprehensive product range - providing all state-of-the-art cable constructions. → Large variety of packaging options - providing minimum scrap and left-over cable sections. → Unique DoubleSafe™ Quality Assurance Program providing lowest rejection rate available. → Full compliance with EU Directive 2011/65/EU (RoHS-2).  | 
		
| PHYSICAL AND MECHANICAL PROPERTIES | ||
| 4 color-coded, individually foil shielded twisted pairs cabled together, overall shielded with a tin-coated copper braid and overall jacketed. Siamese (Figure-8) cables are made of two identical 4-pair cables connected in a zip-cord formation, one cable identified with a longitudinal rib. | |
| Basic Conductor | Solid, 23AWG bare annealed copper | 
| Insulation | Polyolefin | 
| Number of insulated conductors | 8, twisted in 4 pairs. (8 pairs in FIG-8 cables) | 
| Color Code of Pairs | Blue x White, Orange x White, Green x White, Brown x White | 
| Individual pair shield | Polyester-aluminum foil (foil face out), providing 100% coverage | 
| Overall shield | Tin coated copper braid laid in close contact over the inner foils | 
| Outer Jacket | LS0H Halogen free flame retardant or PVC compound | 
| Standard Jacket Color | Light Gray RAL 7035. Other colors available upon request | 
| Standard Surface Marking | Includes HCS P/N, cable description, Meter mark and Batch Number | 
| Pulling force | 50 N/mm2 max | 
| Short Term Bend Radius | 8xOD mm | 
| Long Term Bend Radius | 4xOD mm | 
| Storage temperature | -20 to +60C | 
| Operating temperature | -20 to +60C | 
| Installation temperature | 0 to +50C | 
| Flame Test | IEC 60332-1, IEC 60332-3-22, IEC 60332-3-24 or IEC 60332-3-25 | 
| Conductor Size Test : | UL 444. | 
| LS0H cables gas & smoke tests | IEC 60754 (gas) & IEC 61034 (smoke) |