Fiber Optik Patch Cordlar ve Pigtailler |
DataLight |
| TEKNİK ÖZELLİKLER - İLETİM DEĞERLERİ | ||
| Konnektör Tipi | SC | SC/APC | ST | FC | FC/APC | MT-RJ | LC | MPO / MTP |
| Özellikler | ||||||||
| SM Attenuation |
Select Level 1 to 4 See Below |
Mean:0.2 dB | Mean:0.2 dB | Mean:0.2 dB | Mean:0.2 dB | Mean:0.2 dB |
Select Level 1 to 4 See Below |
Mean:0.35 dB |
| @ 1300nm | Sigma: 0.1dB | Sigma: 0.1dB | Sigma: 0.1dB | Sigma: 0.1dB | Sigma: 0.1dB | Sigma: 0.12dB | ||
| MM Attenuation | - | Mean:0.15 dB | Mean:0.15 dB | - | Mean:0.15 dB | Mean:0.35 dB | ||
| @ 1300nm | - | Sigma: 0.05 dB | Sigma: 0.05 dB | - | Sigma: 0.05 dB | Sigma: 0.12 dB | ||
| SM Return Loss | Min:50 Db Mean: 58dB | Min:65 dB Mean: 80dB | Min:50 dB Mean: 58dB | Min:50 dB Mean: 58dB | Min:65 dB Mean: 80dB | Min:50 dB Mean: 58dB | Min:50 dB Mean: 58dB | Min:55 dB Mean: 60dB |
| MM Return Loss | Min:25 dB D Max:0.2dB | - | Min:25 dB Mean: 27dB | Min:25 dB Mean: 27dB | - | Min:25 dB D Max:0.2dB | Min:25 dB D Max:0.2dB | Min:25 dB D Max:0.2dB |
| SM Connection Dur. | D Max:0.2 dB | D Max:0.2 dB | D Max:0.1 dB | D Max:0.2 dB | D Max:0.2 dB | D Max:0.2dB | D Max:0.2dB | D Max:0.2dB |
| MM Connection Dur. | D Max:0.2 dB | - | D Max:0.2 dB | D Max:0.2 dB | - | D Max:0.2 dB | D Max:0.2 dB | D Max:0.2 dB |
| SM Mating Cycles | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| MM Mating Cycles | 500 | - | 500 | 500 | - | 500 | 500 | 500 |
| Temp. Range | -40 to +85C | -40 to +85C | -40 to +85C | -40 to +85C | -40 to +85C | -40 to +85C | -40 to +85C | -40 to +85C |
Hem SM hem de MM kablolarının ve pigtaillerin zayıflama düzeyi gerektiği gibi seçilmelidir.
Konnektör başına, opsiyonel zayıflama düzeyleri:
4= 0.10 dB
3= 0.15 dB
2= 0.30 dB
1= 0.50 dB
| HCS P/N - Sonlandırılmış Modüler Fiber Optik Cordlar ve Pigtailler | ||
| P/N | Uzunluk | ||||||||
| T | NN | - | X | NN | AB | - | XX | ||
| T | Fiber Tipi | - | Kablo Tipi & Dış Çap | Renk | Konnektörler | - | dm | ||
| Select from | # | Cable | OD mm | ||||||
| HCS Fiber Options Table | A | Bare Fiber | 0.25 | 00=Natürel | 1=ST | nn=dm | |||
| B | Tight-Buffered Fiber | 0.9 | 01=Mavi | 2=SC | An=10m+ | ||||
| E | Simplex LS0H | 1.6 | 02=Turuncu | 3=SC/APC | Bn=20m+ | ||||
| K | Simplex LS0H | 2.0 | 03=Yeşil | 4=FC | Cn=30m+ | ||||
| M | Duplex Zip LS0H | 2.0x4.1 | 04=Kahverengi | 5=FC/APC | Dn=40m+ | ||||
| T | Duplex Zip LS0H | 1.6x3.3 | 05=Gri | 6=MT-RJ - Female | En=50m+ | ||||
| V | Duplex Zip LS0H + 2x28AWG TC Wires | 2.0x4.1 | 06=Beyaz | 8=LC | Fn=60m+ | ||||
| U | Duplex Single-Boot LS0H + Push-Pull Tab | 2.0 | 07=Kırmızı | J=MT-RJ - Male | Gn=70m+ | ||||
| Y | Duplex Single-Boot LS0H + Push-Pull Tab | 3.0 | 08=Siyah | K=LC Duplex + Comm. Pin | Hn=80m+ | ||||
| Z | Duplex Single-Boot LS0H + Push-Pull Tab | 1.6 | 09=Sarı | L=SC Duplex + Comm. Pin | In=90m+ | ||||
| 10=Mor | M=LC/APC | ||||||||
| 11=Turkuaz | N=Mini-LC | ||||||||
| 12=Limon Yeşili | Y=IP68 LC DX/UPC | ||||||||
| 7=E2000 | |||||||||